c0734 CU signal for terminal DO 4
Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group:
Unit: -
Description: Signal for terminal DO 4 (DO+: X132.34 / DO-: X132.44).
Note
DO: Digital Output
c0735 CU signal for terminal DO 5
Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group:
Unit: -
Description: Signal for terminal DO 5 (DO+: X132.35 / DO-: X132.49).
Note
DO: Digital Output
r0747.2...5 Digital outputs status
S200 Basic PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Relay outputs, Digital outputs
Unit: -
Description: Displays the status of digital outputs.
Bit array: Bit Signal name 1 signal 0 signal
02 DO 2 (X132.32) High Low
03 DO 3 (DO+: X132.29 / DO-: X132.33) High Low
04 DO 4 (DO+: X132.34 / DO-: X132.44) High Low
05 DO 5 (DO+: X132.35 / DO-: X132.49) High Low
Note
DO: Digit
al Output
r0747.0...5 Digital outputs status
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Relay outputs, Digital outputs
Unit: -
Description: Displays the status of digital outputs.
Bit array: Bit Signal name 1 signal 0 signal
00 DO 0 (X132.30) High Low
01 DO 1 (X132.31) High Low
02 DO 2 (X132.32) High Low
03 DO 3 (DO+: X132.29 / DO-: X132.33) High Low
04 DO 4 (DO+: X132.34 / DO-: X132.44) High Low
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
618 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA