09 DI 9 (X132.14) High Low
Dependency: See also: p0488, p0489
Note
DI: Digit
al In
put
F
or bits 00, 01: DI 0 and DI 1 ar
e fas
t digital inputs and can be used as measuring probe (p0488, p0489).
c0730 Signal for terminal DO 0
S200 PTI Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Relay outputs, Digital outputs
Unit: -
Description: Signal for terminal DO 0 (X132.30).
Note
DO: Digital Output
c0731 Signal for terminal DO 1
S200 PTI Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Relay outputs, Digital outputs
Unit: -
Description: Signal for terminal DO 1 (X132.31).
Note
DO: Digital Output
c0732 Signal for terminal DO 2
Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Relay outputs
Unit: -
Description: Signal for terminal DO 2 (X132.32).
Note
DO: Digital Output
c0733 CU signal for terminal DO 3
Data type: Unsigned8 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group:
Unit: -
Description: Signal for terminal DO3 (DO+: X132.29 / DO-: X132.33).
Note
DO: Digital Output
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 617

Table of Contents