4: Voltage output (-10 V ... +10 V)
Index: [0] = AO0 (X132.45/46)
[1] = A
O1 (X132.47/48)
Note
When c
hanging p0776, t
he parameters of the scaling characteristic (p0777, p0778, p0779, p0780) are overwritten with
the following default values:
For p0776 = 1 and 4, p0777 is set to 0.0 %, p0778 = 0.0 V, p0779 = 100.0 % and p0780 to 10.0 V.
AO: Analog Output
p0777[0...1] CU analog outputs characteristic value x1
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: %
Min:
-1000.00 [%]
Max:
1000.00 [%]
Factory setting:
0.00 [%]
Description: Sets the scaling characteristic for the analog outputs.
The scaling characteris
tic for the analog outputs is dened using 2 points.
This parameter species the x coordinate (percentage) of the 1st value pair of the characteristic.
Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Dependency: See also: p0776
NOTICE
This parame
ter is automatically overwritten when changing p0776 (type of analog outputs).
Note
The parameters f
or the characteristic do not have a limiting eect.
p0778[0...1] CU analog outputs characteristic value y1
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: V
Min:
0.000 [V]
Max:
10.000 [V]
Factory setting:
0.000 [V]
Description: Sets the scaling characteristic for the analog outputs.
The scaling characteris
tic for the analog outputs is dened using 2 points.
This parameter species the y coordinate (output voltage in V) of the 1st value pair of the characteristic.
Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Dependency: See also: p0776
NOTICE
This parame
ter is automatically overwritten when changing p0776 (type of analog outputs).
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
628 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA