Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Note
AO: Analog Output
r0774[0...1] CU analog outputs output voltage/current actual
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Analog outputs
Unit: V
Description: Displays the actual output voltage at the analog outputs.
Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Dependency: See also: p0776
Note
A
O: Analog Output
p0775[0...1] CU analog outputs activate absolute value generation
S200 PTI Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Analog outputs
Unit: -
Min:
0
Max:
1
Factory setting:
0
Description: Activates the absolute value generation for the analog outputs.
Value: 0: No absolute value generation
1: Absolute value generation switched in
Index: [0] = AO0 (X132.45/46)
[1] = A
O1 (X132.47/48)
Note
AO: Analog Output
p0776[0...1] CU analog outputs type
S200 PTI Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: -
Min:
1
Max:
4
Factory setting:
1
Description: Sets the analog output type.
p0776[x] = 1, 4 corresponds to a volt
age output.
Value: 1: Voltage output (0 V ... +10 V)