c0769[0...1] Analog inputs enable
S200 PTI Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Analog outputs
Unit: -
Description: Signal to enable the analog inputs.
Index: [0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Note
AI: Analog In
put
c0771[0...1] CU analog outputs signal
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Analog outputs
Unit: %
Description: Signal for the analog outputs.
Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Note
AO: Analog Output
r0772[0...1] CU analog outputs output value currently referred
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Analog outputs
Unit: %
Description: Displays the actual referred output value of the analog outputs.
Index: [0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Note
AO: Analog Output
p0773[0...1] CU analog outputs smoothing time constant
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: ms
Min:
0.0 [ms]
Max:
1000.0 [ms]
Factory setting:
0.0 [ms]
Description: Sets the smoothing time constant of the 1st order lowpass lt
er
f
or t
he analog outputs.
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
626 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA