p0766[0...1] Analog inputs activate absolute value generation
S200 PTI Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: -
Min:
0
Max:
1
Factory setting:
0
Description: Activates the absolute value generation of the analog input signals.
Value: 0: No absolute value generation
1: Absolute value generation switched in
Index: [0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Note
AI: Analog In
put
c0767[0...1] Analog inputs inversion
S200 PTI Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Analog outputs
Unit: -
Description: Signal to invert the analog input signals.
Index: [0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Note
AI: Analog Input
p0768[0...1] Analog inputs noise suppression window
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Analog outputs
Unit: %
Min:
0.00 [%]
Max:
20.00 [%]
Factory setting:
0.00 [%]
Description: Sets the window for noise suppression of the analog inputs.
Changes less than the windo
w are suppressed.
Index: [0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Note
AI: Analog Input