Note
The time in r8400 and r8401 is used to display the fault and alarm times.
The date/time ar
e set using the web server (manually).
When the converter is switched o󹪜, date/time are not updated.
After the converter has restarted, the date and time that the converter was in a no-current condition applies.
r8401[0...2] Time
Data type: Unsigned16 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Diagnostics general
Unit: -
Description: Displays the current time in hours, minutes and seconds.
Index: [0] = Hour (0 ... 23)
[1] = Minute (0 ... 59)
[2] = Second (0 ... 59)
Note
The time in r8400 and r8401 is used to displa
y the fault and alarm times.
The time is display
ed in the 24-hour format.
The date/time are set using the web server (manually).
When the converter is switched o󹪜, date/time are not updated. After power on the instant of the previous power o󹪜 is
valid.
c8995[0...3] Ethernet X127 enable
Data type: Unsigned8 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Con󹪝guration
Unit: -
Description: Signal to enable the Ethernet interface X127 for applications.
Index: [0] = Secure S7 Protocol Startdrive
[1] = Web server HTTPS
[2] = S7 pr
otocol PCS7
[3] = Web server HTTP
Note
The parameter in󹪞uences t
he access from applications.
1 signal:
Ethernet interface X127 is enabled for access.
0 signal:
Ethernet interface X127 is blocked and cannot be accessed.
The signal is not in󹪞uenced by restoring the factory settings.
p9603.0 SI control
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Commissioning (Saf
ety Integrated)
Parameter group: Safety Integrated
Unit: -
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 691