Min:
-
Max:
-
Factory setting:
0001 bin
Description: Sets the type of control for the safety functions integrated in the drive.
Bit array: Bit Signal name 1 signal 0 signal
00 Control via F-DI Enable Inhibit
Note
When online saf
ety commissioning has been comple
ted, a change results in an automatic restart.
p9604.0 SI enable
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Commissioning (Safety Integrated)
Parameter group: Safety Integrated
Unit: -
Min:
-
Max:
-
Factory setting:
0001 bin
Description: Sets the enable signal for the safety functions integrated in the drive.
Bit array: Bit Signal name 1 signal 0 signal
00 Enable STO Enable Inhibit
p9670 SI module identication drive
S200 PTI Data type: U
nsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Ready for operation
Parameter group: Safety Integrated
Unit: -
Min:
0
Max:
4294967295
Factory setting:
0
Description: Safety Integrated module identier for the drive.
Replacement of t
he drive is identied when the safety functions are activated.
Note
After replacement, when the dr
ive runs up, an alarm is output
p9699 SI conguration alarm ltering
S200 PTI Dat
a type: Integer16 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Basic functions
Unit: -
Min:
0
Max:
1
Factory setting:
1
Description: Sets the enable for the "Alarm ltering" function.
Value: 0: Deactiv
ate alarm ltering
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
692 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA