p10199 SI reference checksum across device-specic parameter
s chan B
S200 PTI Data type: Unsigned32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Commissioning (Saf
ety Integrated)
Parameter group: Basic functions
Unit: -
Min:
0000 he
x
Max:
FFFF FFFF hex
Factory se
tting:
B2B2 B2B2 hex
Description: Displays the checksum over the checksum-checked parameters for the device-specic paramet
ers of the drive system
(reference checksum) channel B.
Dependency: See also: r10198
r10352.0...15 SI STO select cause
S200 PTI Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Safety Integrated
Unit: -
Description: Reason that STO (Safe Torque O) function was selected.
Bit array
: Bit Signal name 1 signal 0 signal
00 Selection via F-DI High Low
04 Safety commissioning mode active High Low
12 Stop response High Low
14 Response to parameterizing error High Low
15 Response to internal software error High Low
r10452.0...15 SI STO select cause channel B
S200 PTI Data type: U
nsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Safety Integrated
Unit: -
Description: Reason for the selection of function STO (Safe Torque O) on c
hannel B.
Bit arr
a
y
: Bit
Signal name 1 signal 0 signal
00 Selection via F-DI High Low
04 Safety commissioning mode active High Low
12 Stop response High Low
14 Response to parameterizing error High Low
15 Response to internal software error High Low
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
706 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA