c29064 Speed limit selection bit 1
Data type: Unsigned8 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Speed limiting, Technology Extensions
Unit: -
Description: Signal of bit 1 for the speed limit.
c29066 Speed limit
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Technology Extensions
Unit: %
Description: AI channel for speed limitaion
c29067 Speed setpoint
S200 PTI Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Technology Extensions
Unit: %
Description: AI channel for speed setpoint
p29070[0...3] Speed limit in positive direction of rotation
Data type: FloatingPoint32 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Technology Extensions
Unit: rpm
Min:
0.00 [rpm]
Max:
210000.00 [rpm]
Factory setting:
210000.00 [rpm]
Description: Sets the maximum speed for the positive direction.
Thr
ee int
ernal speed limits in t
o
t
al are available.
With the combination of the digital input signals Speed limit selection bit 0 and Speed limit selection bit 1, you can
select one of the three internal speed limits as the source of the speed limit.
Index: [0] = Speed limit for positive direction 0
[1] = Speed limit for positive direction 1
[2] = Speed limit for positiv
e direction 2
[3] = Speed limit for positive direction 3
Dependency: The default value depends on the maximum motor speed.