Section Settings Description
[processing_
systemphase]
StartState= Specifies whether the PCU Installer is active during operation of the Desktop.
Possible values:
activated PCU Installer starts setups
stopped PCU Installer is stopped completely
You can define exceptions in Section "[noactivation]".
scanSetupDirs= Specifies whether setup directories are to be checked and, if required, setup files
executed during Desktop operation.
The following directories are checked if this setting has been activated:
Local setup directories from the [local_setupdirs] setting are always checked.
You can define separately whether additional directories on removable disks or
in the network are to be checked. (See settings "scanRemovableDriveSetupDirs"
and "scanNetworkDriveSetupDirs")
If you deactivate this setting, neither local directories, nor directories on removable
disks or in the network are checked, i.e. the setting scanSetupDirs=no overwrites, for
example, scanNetworkDriveSetupDirs=yes.
Possible values: yes; no
scanRemovableDrive
SetupDirs=
Specifies whether directories on removable disks are to be checked from the setting
[removable_setupdirs] and, if required, setup files executed during Desktop operation.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
scanNetworkDrive
SetupDirs=
Specifies whether network directories are to be checked from the setting [net_setup‐
dirs] and, if required, setup files executed during Desktop operation.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
numberOfScanCycles Specifies whether and how often the setup directories check for new setup packages.
Possible values:
infinite Infinite
Integer
You can define the waiting time between checks in key
waitTimeBetweenScanCycles
waitTimeBetween
ScanCycles
Specifies how long the PCU Installer waits after the setup directories have been
checked before checking them again.
Enter the waiting time in milliseconds.
In key numberOfScanCycles, you can specify how often the setup directories will
be checked.
report InfoLevel Specifies how detailed the information is to be which is stored in the log files.
Possible values:
1: Only basic information on the actions of the PCU Installer is logged
2: All PCU Installer-specific information is logged
3: All PCU Installer-specific information and some trace information is logged
4: All PCU Installer-specific information and additional trace information is logged
5: All PCU Installer-specific information and all trace information is logged
Installing and configuring updates and automation software
5.9 PCU Installer
PCU Base Software (IM10)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 115

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals