Multitool location parameter identifiers (Page 190)
Entries Meaning
HeadLine Column header. Text entered is displayed as a header.
Example: Text "Radius" is displayed as a header (default).
Tooltip Text that is displayed in the tooltip.
Example: Text "Geometry radius" is displayed in the tooltip (default).
ShortText Text if the parameter is displayed in the "More Data" window.
Example: Text "Rad." is displayed in the "More Data" window (default).
DetailsText Text, if the parameter is displayed in the "Details" window.
Example: Text "Radius" is displayed in the "Details" window (default).
Width Column width in pixels in relation to a 640 x 480 resolution.
See example below: The default column width is changed to 53 pixels.
DisplayMode Values that the parameter is displayed with.
See example below: The default setting is changed to "DoubleMode".
The following values can also be accepted:
AnyMode All characters
IntegerMode Integers
UnsignedIntegerMode Unsigned integers
DoubleMode Values with decimal places
The number of decimal places is specified in "Dec‐
imalPlaces"
UnsignedDoubleMode Unsigned values with decimal places
The number of decimal places is specified in "Dec‐
imalPlaces"
Length Specified length
Angle Specified angle
LinearFeedPerTime Linear feed in mm/minute
LinearFeedPerRevolution Linear feed in mm/revolution
LinearFeedPerTooth Linear feed in mm/tooth
RevolutionSpeed Speed
ConstantCuttingSpeed Constant cutting rate
DecimalPlaces Number of decimal places if "DoubleMode" or "UnsignedDoubleMode" is selected
in the DisplayMode.
See example: Two decimal places are entered.
ItemType Field types in which a value is displayed.
TextField Input/output field for values and texts
TextFieldReadOnly Output field for values and texts
CheckBox Input/output field for states
CheckBoxReadOnly Output field for states
BitMask Bit mask for the display of a bit from a value. The bit mask is entered as integer
value. Bit 0 → 1, Bit 1 → 2, Bit 2 → 4
AccessLevel Value for the access level that is used for these parameters in the user interface.
Value range 1 to 7
Tool management
12.2 Configuring the user interface
SINUMERIK Operate (IM9)
192 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals