NOTICE
Basic components are overwritten
If you use numbers less than 500, then it is possible that Siemens basis components will be
overwritten. In the "processes" and "areas" sections, the number range 500 - 999 is
permissible.
Example
[areas]
AREA600= name:=AreaOEM, process:=notepadOEM
AREA601= name:=AreaCalc, process:=calcOEM, panel:=SlHdStdHeaderPanel
Note
Only OEMFrame applications are supported that use programming interfaces of
SINUMERIK Operate.
The [miscellaneous] section
You can make various settings in this section. Generally, only the start operating area is
changed.
Key Value
startuparea
Name of the start operating area
Example
[miscellaneous]
startuparea = AreaOEM
Configuring the operating area menu
The operating area menu is intended for switching over the operating areas configured in the
"systemconfiguration.ini" configuration file. A softkey for selecting the appropriate operating
area is provided on the horizontal softkey bar for each operating area configured.
The operating area displays the names of the operating areas from the
"systemconfiguration.ini" configuration file as the text on the operating area softkeys. The
system automatically searches for a free softkey on the horizontal softkey bar for each
operating area.
SINUMERIK Operate on PC/PCU
23.1 Link OEMFrame application
SINUMERIK Operate (IM9)
664 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1