On switching from one operating area to another, the last active window
ForegroundWindow of the OEMFrame application is saved. When reselecting the
application, the ForegroundWindow window is then reactivated.
The behavior can be changed via the following values:
fForceTaskFocus and fSearchForPopUps
= 1
When the OEMFrame application is deselected, an active popup window is searched for
rather than the ForegroundWindow window.
Behavior of the search:
If a popup window was found, it is displayed when the OEMFrame application is
reselected.
If no popup window exists or was found, the basic window of the application is displayed
when the application is reselected.
Schema fForceTaskFocus/fSearchForPopUps with value 1
2(0)UDPH3RS8S:LQGRZ2(0DSSOLFDWLRQ
%DVLFZLQGRZ
With the following value change, only the basic window of the OEMFrame application is taken
into consideration when an application is selected or deselected. The basic window is specified
in ClassName/WindowName in the "systemconfiguration.ini" file:
Schema fForceTaskFocus with value 1 and fSearchForPopUps with value 0
2(0)UDPH)RUHJURXQG:LQGRZ2(0DSSOLFDWLRQ
%DVLFZLQGRZ
LUUHOHYDQW
fKeepPlacement
This parameter deactivates the resizing (zooming) for the basic window of the OEMFrame
application. By default, the application is zoomed to the screen size before it is displayed. In
the case of applications that do not allow their windows to be zoomed, the resizing can result
in display problems. In such cases, the zoom function must be deactivated.
Example
An application "fixres.exe" should be displayed in its programmed window size. The following
parameter assignment is required:
SINUMERIK Operate on PC/PCU
23.2 Parameterizing the OEMFrame application
SINUMERIK Operate (IM9)
672 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals