EasyManuals Logo

Siemens SINUMERIK ONE MCP 2400.4c Commissioning Manual

Siemens SINUMERIK ONE MCP 2400.4c
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #797 background imageLoading...
Page #797 background image
Tag identifier Meaning
FUNCTION_BODY contin‐
ued
Example:
<function_body name = "test" parameter = "c1,c2,c3" return = "true">
<LET name = "tmp">0</LET>
<OP> tmp = c1+c2+c3 </OP>
<OP> $return = tmp </OP>
</function_body>
<LET name = "my_var"> 4 </LET>
<function name = "test" return = " my_var "> 2, 3,4</function>
<print text = "result = %d"> my_var </print>
REQUEST The tag is used to add a variable to the cyclic reading service (Hotlink). As a consequence,
the access time to variables, which are not linked to the control, is reduced.
If a function is to be called automatically when a value changes, then the name of the function
should be specified as an additional attribute.
This tag is only processed within the INIT operation.
Attributes:
name
Address identifier
function
Function name
Syntax:
<REQUEST name = "<NC-Variable>" />
or
<REQUEST name = "<NC-Variable>" function="<function name>"/>
Example:
<request name ="plc/mb10" />
or
<function_body name="my_function" >
<print text="value changed" />
</function_body>
<request name ="plc/mb10" function="my_function"/>
Generating user dialogs
1.7 XML identifier
Easy XML
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 79

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals