3.3.3 Quality Processing/Affected by the User in CFC Charts.................................................. 74
3.3.4 Quality Processing/Affected by the User in Internal Device Functions............................ 78
3.4 Date and Time Synchronization......................................................................................... 82
3.4.1 Overview of Functions.................................................................................................82
3.4.2 Structure of the Function.............................................................................................82
3.4.3 Function Description....................................................................................................82
3.4.4 Settings.......................................................................................................................85
3.4.5 Information List...........................................................................................................86
3.5 User-Defined Objects........................................................................................................ 87
3.5.1 Overview.....................................................................................................................87
3.5.2 Basic Data Types.......................................................................................................... 88
3.5.3 Energy Metered Values ............................................................................................... 91
3.5.4 Additional Data Types.................................................................................................. 91
3.5.5 External Signals........................................................................................................... 91
3.6 Other Functions................................................................................................................ 92
3.6.1 Indication Filtering and Chatter Blocking for Input Signals ........................................... 92
3.7 General Notes for Setting the Threshold Value of Trigger Functions................................... 95
3.7.1 Overview ....................................................................................................................95
3.7.2 Modifying the Transformer Ratios in DIGSI 5 ................................................................95
3.7.3 Changing the Transformation Ratios of the Transformer on the Device ...................... 102
4 Applications..............................................................................................................................................103
4.1 Overview........................................................................................................................ 104
4.2 Application Template and Functional Scope for the Fault Recorder ..................................105
5 Power-System Data...................................................................................................................................109
5.1 Overview........................................................................................................................ 110
5.2 Structure of the Power-System Data................................................................................ 111
5.3 Application and Setting Notes – General Settings............................................................ 112
5.4 Application and Setting Notes for Measuring Point Current 3-Phase (I-3ph)......................113
5.5 Application and Setting Notes for Measuring Point Current 1-Phase (I-1ph)......................116
5.6 Application and Setting Notes for Measuring Point Voltage 3-Phase (V-3ph).....................118
5.7 Application and Setting Notes for Measuring Point Voltage 1-Phase (V-1ph).....................122
5.8 Settings.......................................................................................................................... 124
5.9 Information List.............................................................................................................. 131
6 Function-Group Types.............................................................................................................................. 135
6.1 Function-Group Type Voltage 3-Phase............................................................................. 136
6.1.1 Overview...................................................................................................................136
6.1.2 Structure of the Function Group................................................................................ 136
6.1.3 Application and Setting Notes....................................................................................138
6.1.4 Settings.....................................................................................................................138
6.1.5 Information List.........................................................................................................139
6.2 Function-Group Type Voltage/current 1-Phase................................................................. 140
6.2.1 Overview of Functions...............................................................................................140
6.2.2 Structure of the Function Group................................................................................ 140
6.2.3 Application and Setting Notes....................................................................................143
Table of Contents
10 SIPROTEC 5, Fault Recorder, Manual
C53000-G5040-C018-5, Edition 11.2017

Table of Contents

Other manuals for Siemens SIPROTEC 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 5 and is the answer not in the manual?

Siemens SIPROTEC 5 Specifications

General IconGeneral
SeriesSIPROTEC 5
Communication ProtocolsIEC 61850, DNP3, Modbus
CybersecurityRole-based access control, secure communication
Modular DesignYes
Hardware RedundancyOptional
Operating Temperature-25°C to +70°C
Digital InputsConfigurable, number depends on I/O modules
Digital OutputsConfigurable, number depends on I/O modules
Analog InputsConfigurable, number depends on I/O modules
Current Transformer InputsConfigurable, number depends on I/O modules
Voltage Transformer InputsConfigurable, number depends on I/O modules
Time SynchronizationIRIG-B, SNTP, PTP
Protection FunctionsOvercurrent, Differential, Distance, Over/Under Voltage, Frequency
Housing19-inch Rack Mount
DimensionsDepends on module configuration
WeightDepends on module configuration
Voltage Input24V DC, 48V DC, 110V DC, 125V DC, 220V DC, 250V DC