Overview
SIPROTEC 5 devices are equipped with an extensive and integrated supervision concept. Continuous supervi-
sion:
Ensures the availability of the technology used
Avoids subfunction and overfunction of the device
Protects persons and primary technical devices
Offers effective assistance during commissioning and testing
The following areas are monitored:
Supervision the resource consumption of the application
Supervision of the secondary system
Supervision of device hardware
Supervision of device firmware
Supervision of hardware configuration
Supervision of communication connections
When the supervision functions pick up, that will be displayed and also indicated. Error responses are defined
for the device. The error responses are grouped in defect severities.
The supervision functions work selectively. When the supervision functions pick up - as far as possible - only
the affected parts of the hardware and firmware are blocked. If this is not possible, the device goes out of
operation into a secure state (fallback mode). In addition to safety, this warrants a high degree of availability.
8.1
Supervision Functions
8.1 Overview
362 SIPROTEC 5, Fault Recorder, Manual
C53000-G5040-C018-5, Edition 11.2017

Table of Contents

Other manuals for Siemens SIPROTEC 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 5 and is the answer not in the manual?

Siemens SIPROTEC 5 Specifications

General IconGeneral
SeriesSIPROTEC 5
Communication ProtocolsIEC 61850, DNP3, Modbus
CybersecurityRole-based access control, secure communication
Modular DesignYes
Hardware RedundancyOptional
Operating Temperature-25°C to +70°C
Digital InputsConfigurable, number depends on I/O modules
Digital OutputsConfigurable, number depends on I/O modules
Analog InputsConfigurable, number depends on I/O modules
Current Transformer InputsConfigurable, number depends on I/O modules
Voltage Transformer InputsConfigurable, number depends on I/O modules
Time SynchronizationIRIG-B, SNTP, PTP
Protection FunctionsOvercurrent, Differential, Distance, Over/Under Voltage, Frequency
Housing19-inch Rack Mount
DimensionsDepends on module configuration
WeightDepends on module configuration
Voltage Input24V DC, 48V DC, 110V DC, 125V DC, 220V DC, 250V DC