Online
If there is a communication connection between a PC program (for example, configuration program) and a
runtime application (for example, a PC application), the PC program is online. The PC program executes in
Online mode.
Order Configurator
One or more appropriate modules are suggested in the order configurator corresponding to the desired
protocol on a module. You will also find the available standard variants in the order configurator.
OSM
See Optical Switch Module.
Output data/output direction
Data is sent from the protocol master to the protocol slave.
Output Indication
Indications can be information provided by the device on events and states. The events and states are
provided via binary outputs, for example, startup of the processor system (event) or fault in a device function
(state). These are designated as output indications.
Parameterization
Comprehensive term for all setting work on the device. You can parameterize the protection functions with
DIGSI 5 or sometimes also directly on the device.
Parameter set
The parameter set is the entirety of all parameters that can be set for a SIPROTEC device.
Participant
In an inter-device communication group, up to 16 SIPROTEC devices suitable for this can communicate with
one another. The individually involved devices are referred to as participants.
Participant Address
A participant address consists of the name of the participant, the international dialing code, the local dialing
code and the participant-specific telephone number.
PDC
See Phasor-Data Concentrator
Phasor-Data Concentrator
PDC. This component collects the information of the PMU devices and makes it available to both other compo-
nents.
Phasor Measurement Unit
The Phasor Measurement Unit (PMU) is a measuring device for power systems. It is capable of taking phasor
measurements of voltages and currents in large, widely distributed networks.
Pinst (Perceptibility, instantaneous)
Perceptibility sensitivity as per flicker measurement according to IEC 61000-4-15
Glossary
480 SIPROTEC 5, Fault Recorder, Manual
C53000-G5040-C018-5, Edition 11.2017

Table of Contents

Other manuals for Siemens SIPROTEC 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 5 and is the answer not in the manual?

Siemens SIPROTEC 5 Specifications

General IconGeneral
SeriesSIPROTEC 5
Communication ProtocolsIEC 61850, DNP3, Modbus
CybersecurityRole-based access control, secure communication
Modular DesignYes
Hardware RedundancyOptional
Operating Temperature-25°C to +70°C
Digital InputsConfigurable, number depends on I/O modules
Digital OutputsConfigurable, number depends on I/O modules
Analog InputsConfigurable, number depends on I/O modules
Current Transformer InputsConfigurable, number depends on I/O modules
Voltage Transformer InputsConfigurable, number depends on I/O modules
Time SynchronizationIRIG-B, SNTP, PTP
Protection FunctionsOvercurrent, Differential, Distance, Over/Under Voltage, Frequency
Housing19-inch Rack Mount
DimensionsDepends on module configuration
WeightDepends on module configuration
Voltage Input24V DC, 48V DC, 110V DC, 125V DC, 220V DC, 250V DC