SNTP
See Simple Network Time Protocol.
SOE
See Sequence of Events.
SP
See Single-Point Indication.
SPC
IEC 61850 data type: Single Point Control
SPS
IEC 61850 data type: Single point status
SST
See System Interface.
Station Description
A station description is an IEC 61850-compliant file for data exchange between the system configurator and
the IED configurator. The station description contains information on the network structure of a substation.
The station description contains for example, information on the assignment of the devices to the primary
equipment, as well as on the station-internal communication.
System Interface
Device interface for linking to the control and protection system via various communication protocols
TC
Tap-position command – see Transformer Tap Position Command
TCP
See Transmission Control Protocol.
Time jump
A step change in the device clock due to user action (setting the time) or automatically (GPS time synchroniza-
tion unit). A time jump may occur, for example, in the event of a failure when changing the time synchroniza-
tion source.
Time stamp
A time stamp is a value in a defined format. The time stamp assigns a point in time to an event, for example,
in a log file. Time stamps ensure that events can be found again.
Topological view
The Topological View is oriented to the objects of a system (for example, switchgear) and their relation to one
another. The Topological View describes the structured layout of the system in hierarchical form.
Transmission Control Protocol
The Transmission Control Protocol (TCP) is a transmission protocol for transport services in the Internet. TCP is
based on IP and ensures connection of the participants during the data transmission. TCP ensures the correct-
ness of the data and the correct sequence of the data packets.
Glossary
SIPROTEC 5, Fault Recorder, Manual 485
C53000-G5040-C018-5, Edition 11.2017

Table of Contents

Other manuals for Siemens SIPROTEC 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 5 and is the answer not in the manual?

Siemens SIPROTEC 5 Specifications

General IconGeneral
SeriesSIPROTEC 5
Communication ProtocolsIEC 61850, DNP3, Modbus
CybersecurityRole-based access control, secure communication
Modular DesignYes
Hardware RedundancyOptional
Operating Temperature-25°C to +70°C
Digital InputsConfigurable, number depends on I/O modules
Digital OutputsConfigurable, number depends on I/O modules
Analog InputsConfigurable, number depends on I/O modules
Current Transformer InputsConfigurable, number depends on I/O modules
Voltage Transformer InputsConfigurable, number depends on I/O modules
Time SynchronizationIRIG-B, SNTP, PTP
Protection FunctionsOvercurrent, Differential, Distance, Over/Under Voltage, Frequency
Housing19-inch Rack Mount
DimensionsDepends on module configuration
WeightDepends on module configuration
Voltage Input24V DC, 48V DC, 110V DC, 125V DC, 220V DC, 250V DC

Related product manuals