EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - Page 159

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3SU12 compact units
7.1 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
159
A function test must be carried out before commissioning. The following properties must be
checked in the function test:
Simultaneous actuation (use of both hands)
Synchronous actuation (synchronism 500 ms)
Relationship between input signals and output signals
Renewed generation of the output signal
For further information refer to Chapters "Mounting (Page 162)", "Two-hand operation
console (Page 244)" and "Application examples (Page 565)".
You can find an overview of the evaluation units that can be used in conjunction with the
sensor switch at this website.
(
https://support.industry.siemens.com/cs/document/109038855/auswertegerte-fr-eine-2-
hand-applikation-mit-dem-3su1200-1sk10-2sa0?pnid=16445&lc=de-WW)
You will find further information about the use of sensor switches in the two-hand operation
console (wiring to Siemens safety relays and safety design) in the following FAQs: "Sensor
switches in the two-hand operation console"
(https://support.industry.siemens.com/cs/document/109479531/Einsatz
)

Table of Contents