AS-Interface 3SU14
11.9 Connecting
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
275
Screw terminal connection
Procedure
1. Insert the connecting lead into the screw terminal
2. Tighten the screws (tightening torque 0.5 to 0.6 Nm)
3. Insert the screw terminal into the AS-i module for front plate mounting
Conductor cross-sections
SZ 3.5 mm x 0.6 mm
0.5 ... 0.6 Nm
4.4 to 5.3 lb in
1 x (0.2 ... 2.5) mm²
2 x (0.2 ... 1.0) mm²
1 x (0.25 ... 2.5) mm²
2 x (0.25 ... 1.0) mm²
1 x (0.2 ... 2.5) mm²
2 x (0.2 ... 1.5) mm²
AWG
1 x 30 to 12