EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - Page 8

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of contents
SIRIUS ACT 3SU1 pushbuttons and signaling devices
8 System Manual, 08/2018, A5E03457306020A/RS-AK/010
12.2 Electronic modules for ID key-operated switches ................................................................ 312
12.2.1 Design of a command point with ID key-operated switch .................................................... 312
12.2.2 Operating principle of the command point with ID key-operated switch .............................. 314
12.2.3 New functions as of firmware 2.0.0 ...................................................................................... 319
12.2.4 Compatibility ......................................................................................................................... 321
12.2.5 Parameters ........................................................................................................................... 322
12.2.5.1 Parameters ........................................................................................................................... 322
12.2.5.2 "Incremental switching mode" parameter ............................................................................ 323
12.2.5.3 "Deactivation of the switch-off function" parameter ............................................................. 323
12.2.5.4 "Switch position memory" parameter ................................................................................... 324
12.2.5.5 “Switch position retentive memory" parameter .................................................................... 324
12.2.5.6 “Individually codable ID keys only" parameter ..................................................................... 325
12.2.5.7 "Switch position delay" parameter ....................................................................................... 325
12.2.5.8 "Select memory range" parameter ....................................................................................... 326
12.2.5.9 "Restore Factory Setting” parameter ................................................................................... 326
12.2.5.10 Manage authorization level (individually encodable ID keys) .............................................. 327
12.2.5.11 Parameters for IO-Link devices (according to IO-Link communication specification
V1.1) ..................................................................................................................................... 333
12.2.6 Process image ..................................................................................................................... 334
12.2.7 Diagnostics ........................................................................................................................... 335
12.2.7.1 IO-Link diagnostics .............................................................................................................. 335
12.2.8 Mounting a command point with ID key-operated switch .................................................... 338
12.2.9 Connecting ........................................................................................................................... 339
12.2.9.1 Electronic modules for the ID key-operated switches for IO-Link ........................................
339
12.3 Electronic modules for IO-Link ............................................................................................. 341
12.3.1 Electronic module for IO-Link ............................................................................................... 341
12.3.2 Functions .............................................................................................................................. 343
12.3.2.1 Input functions ...................................................................................................................... 343
12.3.2.2 Output functions ................................................................................................................... 346
12.3.3 Parameters ........................................................................................................................... 350
12.3.3.1 "Input delay” parameter ........................................................................................................ 351
12.3.3.2 "Inverting input” parameter................................................................................................... 351
12.3.3.3 "Switching input” parameter ................................................................................................. 351
12.3.3.4 "Active edge” parameter input ............................................................................................. 352
12.3.3.5 "Threshold” parameter input ................................................................................................ 352
12.3.3.6 "Inverting output” parameter ................................................................................................ 352
12.3.3.7 "PWM frequency” parameter output .................................................................................... 353
12.3.3.8 "PWM duty cycle” parameter output .................................................................................... 353
12.3.3.9 "Dimming time” parameter output ........................................................................................ 353
12.3.3.10 "Switching output” parameter ............................................................................................... 354
12.3.3.11 "Active edge” parameter output ........................................................................................... 354
12.3.4 Diagnostics ........................................................................................................................... 355
12.3.4.1 IO-Link diagnostics .............................................................................................................. 355
12.3.5 Installing and removing electronic modules for IO-Link ....................................................... 356
12.3.5.1 Installation options ............................................................................................................... 356
12.3.5.2 Installing IO-Link electronic modules for front plate mounting ............................................. 357
12.3.5.3 Mounting position of IO-Link modules for base mounting ................................................... 358
12.3.5.4 Mounting contact modules and IO-Link modules for base mounting ...................................
359
12.3.5.5 Removal of the modules ...................................................................................................... 360
12.3.6 Connecting ........................................................................................................................... 361
12.3.6.1 Electronic modules for IO-Link ............................................................................................. 361
12.3.7 Example of wiring ................................................................................................................. 363