Sets the time to delay car direction changes. Allows time
for passengers to enter their car calls. Units are in 1
second counts.
Parameter default options
Sets the time it takes before an idle car is parked. If set to
zero, parking is disabled.
Enables parking with doors open
Disables the controller from going out of service due to
reoccurring faults
Sets the number of faults allowed within a 1-hour window
before the car goes out of service. If the car goes out of
service, it remains out of service until the hour window
elapses.
Specifies how many times the car may attempt to start a
run in automatic operation during a 1-minute window. If
the controller attempts additional runs, the car goes out
of service until the real-time clock increments to the next
minute. Set this parameter to zero to disable the feature.
When set ON, OOS does not flash on the PI when the car
is out of group
Default learned floor values
Default inputs and outputs
Restore all parameters to factory settings
Set ON to default the FRAM chip. This option is self-
resetting. This clears fault/alarm logs, latched faults,
emergency bits and run counter.
Defaults all miscellaneous values
Calculated NTS velocities
Calculated NTS Position 1 – Normal Profile
Calculated NTS Position 3 – Emergency Power Profile
Calculated NTS Position 4 – Short Profile
Calculated NTS Velocity 1 – Normal Profile