Configuring Notifications
Save
When using this button, the settings for the device selected as the device are saved.
Save multiple
When using this button, a selection box appears from which other devices can be added by checking them.
Save all
When using this button, all of the settings are saved for all of the detected devices.
Using the same settings for several or all of the devices is a good idea when the devices can be compared
with each other. Other than production meters, meters can be largely excluded from this section.
20.6 PM
In the PM tab, two types of email notification types can be activated:
Notification for power reductions.
Notification for master/slave connection problems.
Procedure
Activate this function to receive an e-mail notification for every change to the power reduction
and/or master/slave connection problems.
SAVE the settings.
Notification for power reductions
When Notifications for power reductions have been activated, an email is sent to the configured receiver
e-mail address for every power reduction.
Notification for master/slave connection problems
When the forwarding of control command has been entered under Configuration | Feed-in Management
| Linking, five notifications per day will be sent from each slave when a problem occurs as soon as Notifi-
cation for master/slave connection problems is active.
An e-mail is sent as soon as a slave cannot be reached for at least five minutes. An e-mail is sent again
once the slave is back online.
This e-mail appears in the Notification Overview with the notification type "PM."
Example when a slave is offline:
Communication Status Master/Slave: 12.12.16 - 09:04:31 No response from 192.168.100.110.
Example when a slave is back online:
Communication Status Master/Slave: 12.12.16 - 09:08:37 Response received from 192.168.100.110.

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals