EasyManuals Logo

Solar-Log 2000 Installation Manual

Solar-Log 2000
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
97
Configuring connected devices
18.4.5 Configuring EGO Smart Heaters
EGO Smart Heaters can be selected from the drop-down menu from the Device Configuration menu and
configured accordingly.
Procedure:
Select the Smart Heater from the drop-down menu under devices.
Enter the maximum storage temperature [C°].
The maximum storage temperature can range from 40°C to 80°C . When 0 is entered, the settings
from the Smart Heater for its potentiometer are used.
Configure and active the minimal temperature as needed. Once the temperature falls below this
value, the water is automatically heated to 7° C with the configured output.
Select the operating mode from the meter configuration menu. The EGO Smart Heater can be con-
figured as a consumption meter or a sub-consumer.
Enter the description under Module Fields, Power Output and Descriptions.
SAVE the settings.
Information on the maximum storage temperature for the EGO Smart Heater
By default, the maximum boiler temperature is adjusted with the rotary switch on the EGO Smart Heater.
To be able to control the temperature from the Solar-Log™, the rotary switch on the EGO Smart Heater has
to be set higher than the value from the Solar-Log™ because the settings from the rotary switch determine
the maximum temperature for external control
Example:
If the rotary switch is set to 40°C and the Solar-Log™ to 60°C, the settings from the Solar-Log™ will be
ignored and the value from the rotary switch will be applied. The range for the rotary switch has to be set
higher so that the Solar-Log™ can assume control. In the example to 60°C.
For this reason, we recommend setting the rotary switch to a maximum of 80°C – or the maximum broiler
temperature that is not to be exceeded – when the Solar-Log™ is to control the temperature externally.
The Solar-Log™ can control the temperature when it is in the range below the set maximum value.
Note!
The EGO Smart heater is an intelligent appliance. The available reported surplus is re-
ported to the intelligent electrical appliances and can be consumed by them.
Starting with firmware version 3.5.x, the simultaneous connection of several intelligent
electrical appliances is supported.

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals