Smart Energy
23.3 Smart Energy Surplus Management
The Surplus Management menu is divided into the following sub-sections:
Settings
Surplus priority
(See illustration: "Surplus management")
Fig.: Surplus management
The following values can be defined in the Settings section:
Measurement values for control logic
Surplus offset [%]
The following values for the control logic can be selected under Measurement values for control logic:
Current values
are the instantaneous values. For systems with constant measurements values (e.g. CHP as pro-
ducer), current values can also be used to react more quickly.
Average values
Average values compensate for power fluctuations and help the control logic to operate more
steadily.
Note!
The average value consists of the 5-, 10- or 15-minute average value depending on the
number of connected inverters:
< 30 INV: 5 minutes, 30-59 INV: 10 minutes, >= 60 INV: 15 minutes

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals