Editing Data
21 Editing Data
The Configuration | Data menu offers several functions in regard to the data recorded by the Solar-Log™
and contains the following options:
Initial yield
Data correction
System backup
Backup
Reset
21.1 Initial yield
This function manually imports initial yields from previous recorded daily data into the Solar-Log. This is
useful any time that a large amount of data has to be changed and would take too long with the "Data cor-
rection" function.
The Data import deletes the existing data memory completely before the daily data is imported from a
CSV file. Therefore, the data import should be carried out immediately after the startup of Solar-Log™.
The Initial yield can contain production, consumption or self-consumption values.
Note!
A data import can only be made if all inverters have been correctly detected and config-
ured or if a valid system configuration has been imported.
The data has to be in the CSV format for the import. Files in the CSV format can be created with simple
text editors or spreadsheet programs like MS Excel or Open Office Calc.
The import file must consist of individual rows of text, in which the date and daily yield value in "Wh" (not
kWh!) are separated by semicolons (CSV format).
Example:
DD.MM.YY; Production in Wh; Consumption in Wh; Self-consumption in Wh
12.12.16;136435;264371;33684
13.12.16;138219;213145;43476
etc.
Note: Here, the year value should also consist of 4 digits.
Procedure
Click on Browse.
The file manager of your OS appears.
Select the CSV file that is to be imported
The selected file name is displayed
Click on Upload.
The progress and status of the data import are displayed
Upload file
End current measuring

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals