EasyManua.ls Logo

Solcon HRVS-DN series - User Manual

Default Icon
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
H
H
R
R
V
V
S
S
-
-
D
D
N
N
M
M
e
e
d
d
i
i
u
u
m
m
V
V
o
o
l
l
t
t
a
a
g
g
e
e
D
D
i
i
g
g
i
i
t
t
a
a
l
l
S
S
o
o
f
f
t
t
S
S
t
t
a
a
r
r
t
t
e
e
r
r
6
6
0
0
-
-
1
1
,
,
2
2
0
0
0
0
A
A
,
,
2
2
,
,
3
3
0
0
0
0
-
-
1
1
5
5
,
,
0
0
0
0
0
0
V
V
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
a
a
n
n
d
d
C
C
o
o
m
m
m
m
i
i
s
s
s
s
i
i
o
o
n
n
i
i
n
n
g
g
M
M
a
a
n
n
u
u
a
a
l
l
Ver.27/12/2010

Table of Contents

Questions and Answers

  • J
    Joy JensenSep 9, 2025
    What causes OPEN BYPASS trip after start process in Solcon HRVS-DN?
    • N
      Nicole WeberSep 9, 2025
      An OPEN BYPASS trip after the start process in the Solcon Controller can be caused by: * Verify that Current Gain dip switches are set according to the ratio between the rated current of the starter and the testing motor rated current. * Check Bypass Contactor wiring.
  • K
    Kylie KaneAug 22, 2025
    How to fix incorrect current reading on Solcon HRVS-DN Controller's panel?
    • S
      sarahloveAug 22, 2025
      To address an incorrect current reading on the Solcon Controller's panel: * Verify that the HRVS-DN FLC setting parameter is set according to the rated current of the starter. * Check the Current Gain dip switches settings. If both Gain dip switches of phases are set to on, the gain = 1. If Gain dip switches # 1 of phases are set to off, the gain = 5. If Gain dip switches # 2 of phases are set to off, the gain = 13.4. If both Gain dip switches of phases are set to off, the gain = 67. * Use a Clamp-on the Ammeter to measure test the motor current. * The starter’s current reading should be approximately the actual current multiplied by the gain ratio set by the Gain dip switches. * You can also set parameters to default parameters and re-program the HRVS-DN.
  • M
    monicacampbellSep 6, 2025
    Why does Solcon Controller motor vibrate at the end of starting or beginning of soft stop?
    • M
      Mr. Russell BlackwellSep 6, 2025
      If the motor vibrates mechanically at the end of the starting process or at the beginning of a soft stop, and the current fluctuates with the Solcon Controller: * This phenomena may occur with unloaded or lightly loaded motor, if SOFT START CURVE 0 is used. * Use standard curve SOFT START CURVE 1 and SOFT STOP CURVE 1.
  • M
    Michael MeltonSep 5, 2025
    How to troubleshoot UNBALANCE CURRENT trip after starting Solcon Controller?
    • F
      flynnjoelSep 5, 2025
      To troubleshoot an UNBALANCE CURRENT trip after starting the Solcon Controller: * Verify, by reading currents on the display, that the three current readings are identical (before the trip). * Check that fiber optic wires 1, 3 & 5 are properly connected to the Control Module. * Check that the current Gain dip switches are set identically in the three phases. * Verify that current flows in all three phases. * If there is no current display on one phase: * Change to SOFT START CURVE 0 (basic). * Try to start. * If the problem still exists perform a firing test.
  • K
    Kara KeithSep 4, 2025
    What causes PHASE LOSS trip in Solcon Controller after starting?
    • J
      Jacqueline HawkinsSep 4, 2025
      A PHASE LOSS trip after starting the Solcon Controller may be caused by: * Verify that all three phases are within range. * Verify that EPT-Tx and EPT-Rx fiber optic wires are properly connected. * If low voltage mains is powered from a generator, check that frequency is within the range of 46Hz < f
  • M
    mitchell55Sep 2, 2025
    How to fix TOO MANY STARTS trip on Solcon HRVS-DN Controller?
    • B
      Brian EdwardsSep 2, 2025
      If a TOO MANY STARTS trip occurs immediately after starting the Solcon Controller: * The default setting allows for one start per 20 minutes. * To reset the fault find the NUMBER OF STARTS setting at the end of the START PARAMETERS page, increase setting to OFF, then reset. Store at the end of the page. * Be sure to set for medium voltage operation after end of testing.
  • A
    allenstephanieSep 1, 2025
    What to do if PWR ON & NO STRT Trip occurs before starting Solcon Controller?
    • S
      Steven AndersonSep 1, 2025
      The PWR ON & NO STRT Trip occurs before starting the Solcon Controller when mains voltage is connected to the HRVS-DN for more than 30 seconds without a start signal. It may also occur if mains voltage is connected downstream (“below”) from the Line Contactor instead of upstream (“above”) the Line Contactor. The starter protects itself from overheating. This function can be disabled for special applications.
  • M
    Michelle ConnerAug 30, 2025
    Why does O/C-SHEAR PIN trip occur when starting Solcon Controller?
    • B
      Bradley SmithAug 30, 2025
      An O/C-SHEAR PIN trip immediately after starting the Solcon Controller could be due to: * Verify that Current Gain dip switches are set according to the ratio between the rated current of the starter and the testing motor rated current. * The trip can occur if added (by setting of Gain dip switches) gain is too high. * Try to start with SOFT START CURVE 0 and stop with SOFT STOP CURVE 0. If problem is solved the current transformers and their wiring should be checked. * Check that all fiber optic wires are properly connected.
  • V
    Victoria RamirezAug 29, 2025
    What causes GROUND FAULT trip after starting Solcon Controller?
    • D
      Daniel HayesAug 29, 2025
      A GROUND FAULT trip after starting the Solcon Controller may be due to: * View the three currents on starter’s display. * Check that the current Gain dip switches are set identically in the three phases. * Verify that an output cable to the motor is not short circuited to the chassis ground. * Verify that two wires of a CT are not swapped (can occur only if user changed CTs wiring! ) Note: SUCH ACTION WILL VOID MANUFACTURER’S WARRANTY ! * Disconnect the low voltage motor. Check motor insulation with a Megger tester.
  • Q
    qhessAug 27, 2025
    How to resolve PHASE SEQUENCE trip in Solcon HRVS-DN Controller?
    • C
      crojasAug 27, 2025
      If a PHASE SEQUENCE trip occurs immediately after starting the Solcon Controller, it indicates that the phase sequence of the mains lines is incorrect. You have two options to resolve this: 1. Swap two input lines. 2. Set the PHASE SEQUENCE setting in FAULT PARAMETERS as required.

Summary

Safety and Warnings

Safety Precautions and Warnings

General safety precautions, attention notes, and critical warnings for operation.

Installation of IP00 (OEM Kit) in a Cabinet

Mounting and Environmental Considerations

Guidelines for mounting, clearances, and operating temperature limits.

Control Keypad

Parameter Navigation and Special Modes

How to navigate parameters and perform special functions like self-test.

Motor and Soft Starter Protection

Adjustable Protection Functions

Details various adjustable protection functions like Under Current, Overload.

Fault Management and Reset

Procedures for handling faults, resets, and auto-reset functionality.

Commissioning and Operation Manual

Operational Notes and Safety Precautions

Important notes and safety precautions before operation and commissioning.

High-Pot Test of the HRVS-DN CABINET

High-Pot Test Procedures

Detailed procedures for performing high-pot tests under various configurations.

Test Procedure for Low Voltage Testing

Test Setup and Prerequisites

Lists required accessories and important notes/warnings for testing.

Low Voltage Test Procedure and Settings

Step-by-step guide for low voltage tests, including switch and harness setup.

Start Procedure for Medium Voltage Motor

Pre-Start Checks and Attention Notes

Critical checks and attention notes before starting medium voltage motors.

Medium Voltage Test Procedure

Step-by-step guide for testing medium voltage motors.

Motor Starting Procedures and Curves

Guides on starting processes, curves, and dual adjustment.

Trouble Shooting

Resistance and Firing System Checks

Procedures for checking resistances and the thyristor firing system.

Low Voltage Test Troubleshooting

Solutions for problems encountered during low voltage testing.

Medium Voltage Trouble shooting

Troubleshooting guide for medium voltage operation and motor connection issues.

HRVS-DN Communication (Modbus Protocol)

HRVS-DN Communication (Profibus Protocol)

HRVS-DN Communication (DeviceNet)

Main, Start, Stop, Dual, and Fault Settings Objects

DeviceNet parameters for main, start, stop, dual, and fault settings.

Parameters List

Main & Protect. Parameters

Comprehensive list of main and protection parameters with ranges and defaults.

Solcon HRVS-DN series Specifications

General IconGeneral
TypeMedium Voltage Soft Starter
Voltage2.3kV up to 13.8kV
CurrentUp to 1200A
Starting MethodSoft Start
BypassOptional
ProtectionPhase Loss
CommunicationModbus RTU, Profibus, Ethernet
CoolingForced Air