6-54
2. VTR & CAM mode ON
Mode Stop
Signal Any signal
Adjustment Page F
Adjustment Address 02
Adjustment procedure:
How to cancel the VTR &CAM mode ON.
Order Page Address Data Procedure
1 Set the remote commander (RM-95) to HOLD (adjustment position), and turn on the
UNREG power supply.
2 6 00 01 After setting the data, press the PAUSE button. (Preparation)
3 F 02 03 After setting the data, press the PAUSE button.
4 Turn off the UNREG power supply once, then turn it on.
Order Page Address Data Procedure
1 6 00 01 After setting the data, press the PAUSE button.
2 F 02 00 After setting the data, press the PAUSE button.
3 Turn off the UNREG power supply once, then turn it on.