6-59
11. Individual operation of drum, capstan and loading
motor
Data Operation
00 Normal
02 Drum rotation in normal direction
06 Capstan rotation in normal direction
08 Capstan rotation in reverse direction
0A Loading motor rotation in normal direction
0C Loading motor rotation in reverse direction
01
03
05
07
09 All motors stop.
0B
0D
0F
Operating procedure:
12. Drum use history check
Page 0 Address 02 to 04
How to use:
1) The record of use data is displayed at addresses : 02 to 04 on
page 0.
Note : This data will be cleared when the button battery is removed
(reset). Be sure to read the data before disassembling the
set.
Order Page Address Data Procedure
1 2 00 02 After setting the data, press the PAUSE button.
2 7 0E 01 Individual operation of motors is approved.
3 7 11 Motor can be operated individually by setting the above
described data.
4 Turn the main power (7.2V) OFF.
Address
02
03
04
Function
Accumulated drum rotation time
(BCD code)
Remarks
10th digit and 1st digit of the accumulated time
(decimal numbers)
1000th digit and 100th digit of the accumulated time
(decimal numbers)
Hour
×100 Hour
Minute
Note : Check the motors after removing the tape.