Chapter 11 DME Operations
686
DME Special Effect Operations
The procedure for selecting the input signal in the <Back Video> group is the
same as for the Page Turn menu.
For details about operation, see “Page Turn settings” (page 683).
Notes
When using a cylinder effect with one channel, the following restrictions
apply.
In an MVE-8000 or MVE-8000A HD system, when the input is for example a
title, parts of the inner surface other than the title appear as black.
Sphere settings
You can set the degree of winding onto the sphere, the radius, the horizontal
position of the wound image, and front and back side output for the image.
Notes
You cannot monitor the part of a rotating sphere that corresponds to its axis on
the monitor screen.
To apply the Sphere effect
Display the Sphere menu.
The knobs in the Sphere menu have the same functions as those in the Cylinder
menu.
For details about operation, see “Cylinder settings” (page 685).
Notes
When using a sphere effect with one channel, the following restrictions apply.
In an MVE-8000 or MVE-8000A HD system, when the input is for example a
title, parts of the inner surface other than the title appear as black.
Explosion settings
You can set the pattern shape and aspect ratio, the center position, the amount
of movement by fragments, the curvature of the transition path, and other
parameters.
To apply the Explosion effect
With the Explosion menu displayed, use the following procedure.
1
In the <Mode> group, select the explosion pattern.
•Circle
• Rectangle