Chapter 20 Switcher Setup (Switcher)
1194
Settings Relating to Keys, Wipes, Frame Memory and Color Correction (Key/Wipe/FM/CCR Menu)
Selecting the processing order of masks and borders
In the <Mask/Border Process> group of the Switcher >Key/Wipe/FM/CCR
menu, select one of the following.
Mask >Border: Apply the Mask effect, then apply the Border effect.
Border >Mask: Apply the Border effect, then apply the Mask effect.
Selecting the key priority operation mode
In the <Key Priority> group of the Switcher >Key/Wipe/FM/CCR menu, select
one of the following.
Normal: The key priority sequence can be varied freely.
Fix: Fixed at currently set priority sequence.
Setting the operation mode of the key bus [XPT HOLD] button
In the <Xpt Hold Mode> group of the Switcher >Key/Wipe/FM/CCR menu,
select any of the following. This setting is applied for the attributes of
snapshots as well as the operation mode of [XPT HOLD] button.
Key Disable: The [XPT HOLD] button of the key bus functions not only as a
cross-point hold button but also as a key disable button. When the [XPT
HOLD] button is on, recalling a snapshot or keyframe effect does not
reflect the key settings, including the cross-point selection information.
Key Disable with Status: Same as [Key Disable], and further disables the
reflection of the key on/off status.
Xpt Hold: The [XPT HOLD] button of the key bus functions as a cross-point
hold button. When the [XPT HOLD] is on, recalling a snapshot or
keyframe effect does not reflect the cross-point selection information.
To change the cross-point hold attribute of a snapshot
If you select “Key Disable” above, this also applies key disable to the cross-
point hold attribute.
If you select “Key Disable With Status,” the key disable function is applied,
including the key on/off status.
Setting the operation mode when the pattern limit is released
In the <Pattern Limit Transition> group of the Switcher >Key/Wipe/FM/CCR
menu, select either of the following operation modes.
Auto: When the pattern limit is released, the remainder of the transition is
carried out automatically at a special-purpose transition rate.
Manual: After the pattern limit is released, the transition waits for the next
operation, then executes. Until you move the fader lever or press [AUTO
TRANS], the transition is not executed.