Chapter 16 Macros
932
Macro Operations in the Simple Type Flexi Pad Control Block
In the simple type Flexi Pad control block, it is not possible to undo a macro
save.
Specifying an edit point
1
In the Flexi Pad control block, press the [MCRO] button, turning it on.
This assigns the Flexi Pad control block to macro operation.
2
While holding down the [MCRO] button in the Flexi Pad control block,
press the button in the memory recall section showing the desired register
name.
3
Specify the edit point by the following operation.
To move the edit point to the event immediately following the current
macro event (the macro event specified as the current edit point), press
the [NEXT] button.
To move the edit point to the event immediately preceding the current
macro event, press the [PREV] button.
Inserting an event
To add an event to an already created macro, use the following procedure.
1
Specify the edit point. (See page 932.)
2
Carry out the event to be added on the control panel.
For details of events that can be registered, see “Events” (page 902).
3
In the memory recall section, press the [INS] button.
This adds the new event after the event specified in step 1.
Modifying an event
1
Specify the edit point. (See page 932.)
2
Carry out the event you want to modify on the control panel.
3
Press the [MOD] button.
This modifies the event at the specified edit point as carried out in step 2.