Oscillator Type @ 1Hz @ 10Hz @ 100Hz @ 1KHz @ 10KHz
Rubidium ˗80 ˗98 ˗120 ˗140 ˗140
Low-phase noise OCXO ˗100 ˗128 ˗148 ˗153 ˗155
OCXO ˗95 ˗123 ˗140 ˗145 ˗150
TCXO ./. ./. ˗110 ˗135 ˗140
1.7.8 Mechanical and Environmental Specifications
Dimensions:
Designed for EIA 19” rack mount:
Housing w/o connectors and brackets:
16.75 W x 1.72” H [1U] x 14.33” D actual
(425 mm W x 44 mm H x 364 mm D)
Weight:
6.0 lbs (2.72 kg)
Temperature:
Operating:
-20°C to +65°C
Storage:
-40°C to +85°C
Humidity:
10% - 95% relative humidity, non-condensing @ 40°C
Altitude:
Operating:
100-240 V
AC
: up to 6560 ft (2000 m)
100-120 V
AC
: up to 13123 ft (4000 m)
12-17 V
DC
and 21-60V
DC
: up to 13125 ft (4000 m)
Storage range:
up to 45000 ft (13700 m)
Shock:
Operating: 15g/0.53 oz, 11ms, half sine wave
SAASM GPS storage shock specs: MRU 35g, GB-GRAM 40g
Storage: 50g/1.76 oz, 11ms, half sine wave