: Colon Separator
HH Hours (00-23)
MM Minutes (00-59)
SS Seconds (00-59) (00-60 for leap second)
Q Time Sync Status [as INPUT]
space = SYNC
. = SYNC
*’=NOT IN SYNC
#’ = NOT IN SYNC
? = NOT IN SYNC
Q Time Sync Status [as OUTPUT]
space = Time error is less than time quality flag 1's threshold (TFOM < or = 3)
. = Time error has exceeded time quality flag 1's threshold (TFOM = 4)
*” = Time error has exceeded time quality flag 2's threshold (TFOM = 5)
#” = Time error has exceeded time quality flag 3's threshold (TFOM = 6)
? = Time error has exceeded time quality flag 4's threshold OR a reference source is unavailable
(TFOM >=7)
CR Carriage Return (ASCII Character 13)
LF Line Feed (ASCII Character 10)
The leading edge of the first character (CR) marks the on-time point of the data stream.
5.4.12.1 Format 9S
Format 9S is a variation of ASCII Format 9 that uses Sysplex compatible fields indicating
sychronization status:
512 SecureSync User Reference Guide