Title Reference
NTP NTP input
User Host (time is manually set by the user)
HAVEQUICK HAVEQUICK input
The number displayed indicates the number of feature inputs of that type presently installed in
the SecureSync– starting with 0” representing the first feature input. For example:
IRIG 0 = 1
st
IRIG input instance
Frequency 1 = 2nd frequency input instance
NTP 2 = 3rd NTP input instance
The columns of the Reference Priority table are defined as follows:
PriorityDefines the order or priority for each index (row). The range is 1 to 16, with 1
being the highest priority and 16 being the lowest priority. The highest priority ref
erence that is available and valid is the reference that is selected.
Time—The reference selected to provide the necessary “Time” reference.
1PPS—The reference selected to provide the necessary “1PPS reference.
EnabledThe reference is enabled.
DeleteRemoves the Index (row) from the Reference Priority table.
3.3.1.1 Configuring Input Reference Priorities
SecureSync can use numerous external time sources, referred to as "references". As external
time sources may be subject to different degrees of accuracy and reliability, you can determine
in which order (= priority) SecureSync calls upon its external time and 1PPS references.
For additional information, see also "Input Reference Priorities" on page155.
Accessing the Reference Priority Screen
To access the Reference Priority Setup screen:
1.
Navigate to MANAGEMENT > OTHER: Reference Priority.
OR:
3.3 Managing References
CHAPTER 3 SecureSync User Reference Guide Rev. 23