DD Numerical Day of Month (1-31)
MMM Month (JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC)
YY Year without century (99, 00, 01, etc.)
HH Hours (00-23)
: Colon separator
MM Minutes (00-59)
SS Seconds (00-60)
The leading edge of the first character (CR) marks the on-time point of the data stream.
The time synchronization status character (I) is defined as described below:
? When the receiver is unable to track any satellites and the time synchronization lamp is red.
* When the receiver time is derived from the battery backed clock or set manually through the Setup Port
Interface.
E x a m p l e :
FRI 20APR15 12:45:36
The example data stream provides the following information:
Sync
Status
The clock is not time synchronized to GNSS. Time is derived from the battery backed clock or
set manually.
Date Friday April, 23, 2015
Time 12:45:36
5.3.7 Spectracom Format 2
This format provides a time data stream with millisecond resolution. The Format 2 data stream
consists of indicators for time synchronization status, time quality, leap second and Daylight
Saving Time. Time data reflects UTC time and is in the 24-hour format. Format 2 data structure
is shown below:
252 VersaSync User Manual
APPENDIX

Table of Contents