Do you have a question about the Spectracom VersaSync and is the answer not in the manual?
Provides initial steps and guidance for new users of the VersaSync system.
Introduces the integrated web user interface for configuring and monitoring the unit.
Outlines the steps for hardware setup, mechanical installation, and physical connections.
Provides information to establish a network connection and access the Web UI.
Details how to access the VersaSync Web User Interface for configuration and status.
Guides on assigning an IP address, subnet mask, and gateway for network access.
Covers the configuration of inputs and outputs via the I/O connector using the Web UI.
Explains how to configure network settings for VersaSync access and monitoring.
The main entry point for all user-configurable System Time related settings.
Explains how VersaSync maintains and uses its System Time for outputs and synchronization.
Discusses time and frequency sources, input reference priorities, and synchronization.
Details how to determine the order of priority for external time and 1PPS references.
Details how the VersaSync utilizes the GNSS signal as a primary timing reference.
Describes the mode where VersaSync maintains time outputs from its internal oscillator when references are lost.
Covers managing user accounts, permissions, and password policies for system security.
Details how to access and interpret detailed status information via the VersaSync Web UI.
Guides on how to perform software updates to get the latest features and fixes.
Provides information on troubleshooting failure symptoms using the Web UI status.
Provides initial steps and guidance for new users of the VersaSync system.
Introduces the integrated web user interface for configuring and monitoring the unit.
Outlines the steps for hardware setup, mechanical installation, and physical connections.
Provides information to establish a network connection and access the Web UI.
Details how to access the VersaSync Web User Interface for configuration and status.
Guides on assigning an IP address, subnet mask, and gateway for network access.
Covers the configuration of inputs and outputs via the I/O connector using the Web UI.
Explains how to configure network settings for VersaSync access and monitoring.
The main entry point for all user-configurable System Time related settings.
Explains how VersaSync maintains and uses its System Time for outputs and synchronization.
Discusses time and frequency sources, input reference priorities, and synchronization.
Details how to determine the order of priority for external time and 1PPS references.
Details how the VersaSync utilizes the GNSS signal as a primary timing reference.
Describes the mode where VersaSync maintains time outputs from its internal oscillator when references are lost.
Covers managing user accounts, permissions, and password policies for system security.
Details how to access and interpret detailed status information via the VersaSync Web UI.
Guides on how to perform software updates to get the latest features and fixes.
Provides information on troubleshooting failure symptoms using the Web UI status.
| Model | VersaSync |
|---|---|
| Operating Temperature | -20°C to +65°C |
| Category | Time and Frequency Server |
| GNSS Receiver | GPS, GLONASS, Galileo, BeiDou |
| Inputs | 1PPS, 10 MHz, IRIG-B, NTP, PTP |
| Outputs | 1PPS, 10 MHz, IRIG-B, NTP, PTP |
| Network Interfaces | Ethernet (10/100/1000 Mbps) |
| Synchronization Protocols | PTP (IEEE 1588-2008), NTP |
| Frequency Accuracy | 1 x 10-12 (GNSS locked) |
| Power Supply | 100-240 VAC, 50/60 Hz |
| Form Factor | 1U Rackmount |