S CLASS2 cutter User’s Manual
Specifications 6-7
6.2.7 Environmental
(Cutter without media)
Operating Temperature 15 to 35° C 59 to 95° F
Storage temperature -30 to 70° C -22 to 158° F
Relative humidity 35 - 75 %, non-condensing
FIG 6-7
6-7 S CLASS 2 ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT: The use of dimensionally stable media is an essential pre-
requisite to obtain high cut quality. Additionally, media expansion or contraction
may occur as a result of temperature variations. To improve the dimensional
stability of media, let it stabilize to the current environmental conditions before
use, for a minimum period of 24 hours.
6.2.8 Electrical
Operating voltage: 100-240V 50/60 Hz
Fuse T2AH 250V Schurter SPT or equivalent.
WARNING:
For continued protection against risk of fire, replace only with the same
type and rating of fuse.