14-8 ELECTRICAL SYSTEM
IGNITION SYSTEM COIL INSPECTION
• Disconnect the magneto lead wire coupler
1.
• Measure the exciter, charge and pick-up coils resistance.
# Stator coil resistance
# Pick-up coil resistance
! 09900-25008: Multi-circuit tester set
& Tester knob indication: Resistance (Ω)
If the resistance is not within the standard range, replace the
stator assembly with a new one.
Exciter Black/Red – Red/White 24 – 42 Ω
Charge Yellow – Black/White 1.6 – 3.2 Ω
Pick-up Red – Green 72 – 127 Ω