134 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
Alarm Messages
9 IOCINCOMP Minor IOC 1, IOC 2
incompatible
Indicates that
redundant IOC
modules are not
compatible
Need to upgrade
IOCs to same
firmware version
IOC 1, IOC 2
compatible
Indicates that
redundant IOC
modules are
compatible
No action required
IOC 2, IOC 1
incompatible
Indicates that
redundant IOC
modules are not
compatible
Need to upgrade
IOCs to same
firmware version
IOC 2, IOC 1
compatible
Indicates that
redundant IOC
modules are
compatible
No action required
10 CLKEXTHOLD Critical IOC <#> has
been in Holdover
Mode for
extended period
Indicates that
the specified
IOC has been in
Holdover mode
for an extended
period
Check cable and
NE providing input
on that port
IOC <#> has
transitioned out
of extended
Holdover Mode
Indicates that
the specified
IOC (IOC1 or
IOC2)
is now out of
extended
holdover mode
No action required
11 XSYNCLOS Major Xsync between
IOCs lost
Indicates that
the Xsync
between IOC
modules is lost
Re-seat the IOC
module, if issue
not resolved,
replace module
Xsync between
IOCs recovered
Indicates that
the Xsync
between IOC
modules has
been restored
No action required
Table A-2. System Notification Messages - Alarms (Continued)
Index
Trap Name
(trapID)
Severity
(default)
Trap Messages
(trapDescription)
Description
Corrective
Action