097-93100-01 Revision C – February, 2010 TimeCreator 1000 User’s Guide 179
Appendix B Command Descriptions and Communications Interface
CLI Commands
Show Alarm-State
This command displays the state of each alarm: if it is enabled or disabled.
Command Syntax:
show alarm-state
Example:
tc1000>show alarm-state
Response:
IOC Failed - enable
IMC Failed - enable
IMC Communication - enable
IOC Communication - enable
Output Disconnected - enable
Input Disconnected - enable
Input Cable Advance - enable
Input Unstable - enable
Input Disqualified - enable
IOC Incompatible - enable
IMC Incompatiable - enable
Ext Hold - enable
GPS Communication - enable
MTIE Threshold - enable
MTIE 35 Threshold - enable
PP Jitter Threshold - enable
FER Threshold - enable
Power Output - disable
Power Fan - disable
IOCs Removed - enable
JamSync - enable
XSYNC Loss - enable
DCM unlocked - enable
PLL unlocked - enable
Remarks: See the list of alarm codes in the Set Alarm-State command.
Related:
set alarm-state
Level : User, Power-User and Admin