180 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix B Command Descriptions and Communications Interface
CLI Commands
Set Alarm-State
This command is used to enable or disable specific alarms. Table A-2 provides a list
of alarm codes and their description.
Command Syntax:
set alarm-state <alarm code> {enable|disable}
Example:
To enable the alarm for IOC in holdover for extended period (alarm code of EXTHOLD) -
tc1000>set alarm-state exthold enable
Related: show alarm-state
Level: Power-User and Admin only
Table B-1. TimeCreator 1000 Alarm Codes
Alarm Code Description
IOCFAIL
IOC card failure
IMCFAIL
IMC card failure
IMCCOM
IMC communication failure
IOCCOM
IOC communication failure
OUTDISC
DTI output disconnect
INPDISC
DTI input disconnect
INPCBLADV DTI input cable advance invalid
INPUNSTBL
DTI input performance unstable
INPDISQ
DTI Input disqualified
IOCINCOMP
IOC cardss are incompatible
IMCINCOMP
IMC and IOC are incompatible
EXTHOLD
IOC in holdover for extended period
GPSCOMM
GPS communications failure
MTIET
MTIE-t threshold exceeded
MTIE35
MTIE-35 threshold exceeded

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals