216 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix B Command Descriptions and Communications Interface
CLI Commands
To provision the interval over which jitter performance data is calculated for the
specified port-
set interval jitter [port#|all] <value>
To provision the interval over which MTIE-t performance data is calculated for the
specified port-
set interval mtie-t [port#|all] <value>
To provision the interval over which Frame Error Rate (FER) performance data is
calculated for the specified port-
set interval fer [port#|all] <value>
Example 1:
To set the interval for jitter calculations for all ports to 20 -
tc1000>set interval jitter all
Example 2:
To set the interval for MTIE-t calculations for Port 5 to 40 -
tc1000>set interval mtie-t port 5 40
Example 3:
To set the interval for MTIE-t calculations for Port 10 to 15 -
tc1000>set interval fer port 10 15
Remarks: The range is 0 to 1000. Setting the interval to 0 disables calculation of
performance data.
Level : Power-User and Admin only

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals