Chapter 9
158
UM10372_PCNC440_Manual_0221A
MAiNTENANCE
9. MAiNTENANCE
9.1 Regular Maintenance
Scheduled maintenance intervals are detailed in the table below.
Mill Maintenance Schedule
Frequency Completed Item
Daily
Check oiler level and top o as needed (0.25 quart capacity)
Retract and release manual oiler plunger each me mill is powered on and aer
every four hours of operaon
Clean chips from ways, carriage, and bellows’ covers
Spray exposed, non-painted metal surfaces with WD-40
®
or similar to prevent rust
Weekly
Check drawbar for wear; grease and adjust if needed
Check air gauge/regulator for proper PSI (90 PSI minimum)
Use mild cleaner to clean all exterior surfaces (no solvents)
Monthly
Inspect electrical cabinet vent and fan lter for dust build-up and wipe with a clean
cloth if necessary; if dust accumulaon is excessive, remove with compressed air
Pull back way covers and inspect ways and ball screw for proper lubricaon (on all
axes)
Every Six
Months
Inspect spindle belt for nicks, fraying, or other noceable signs of wear
Inspect way covers as needed to ensure proper operaon; replace as needed
Inspect oil system for blockages; clean/replace as needed
Check lubricaon hoses for signs of wear or cracking; replace as needed
Check X-axis ex conduit for signs of wear or cracking; replace as needed
Every 12
Months
Check door switch for proper funcon; replace as needed