Chapter 2
23
UM10372_PCNC440_Manual_0221A
SiTE PlANNiNg ANd PREP
2.2.4 Electrical Noise
Primary power should be provided by a dedicated circuit. At the minimum, it should be isolated from
electrically-noisy devices. In parcular, high-inducve loads from vacuum cleaners, air compressors,
etc., can be troublesome and the source of controller malfuncon.
At sites where this is not possible, a double-conversion uninterrupble power supply (UPS) should
be considered for 115 VAC circuits.
2.2.5 Options for Electrically Non-conforming Sites
The following device may be considered for sites that do not conform to the electrical requirements
detailed in this secon. Consult with an electrician to determine suitability for the specic site.
• Step-up/Step-down Transformer (PN 32009): used to reduce 230 VAC line voltage to 115 VAC,
as required by the PCNC 440; commonly used for PCNC 440 mills located outside of the USA
and Canada.