Chapter 2
22
UM10372_PCNC440_Manual_0221A
SiTE PlANNiNg ANd PREP
NOTE: Allocate addional space to allow access to rear of mill for maintenance or repairs.
2.2 Electrical Requirements
WARNING! Electrical Shock Hazard: Electrical connecons must be performed by a cered
electrician. Failure to do so may result in death and/or serious injury.
Primary Recommended Circuit Amperage
115 VAC, 50/60 Hz 15 A
2.2.1 Grounding
All power inputs to the PCNC 440 must be properly grounded. Check connuity between bare metal
on mill frame and true earth ground (water pipe or similar) to ensure proper grounding.
2.2.2 Plug Pattern
The PCNC 440 is shipped with a 3-prong plug. This plug is designed to be used with a 3-prong outlet.
2.2.3 Ground Fault Interrupter (GFI) Use
Primary power for the PCNC 440 should not be protected by a ground fault interrupter (GFI), as this
interferes with the proper operaon of the PCNC mill’s spindle controller.