EasyManua.ls Logo

Tormach PCNC 440 - Page 168

Tormach PCNC 440
183 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9
168
UM10372_PCNC440_Manual_0221A
MAiNTENANCE
IMPORTANT! The PCNC 440 must be removed from the Tormach stand (if equipped) for transport. The
stand is not designed to support the weight of the mill during transport.
Warranty is void if the mill is disassembled. Tormach recognizes that there are situaons where
operators need to disassemble their mill and has made provisions in the design of the mill to facilitate
this. Nevertheless, Tormach cannot be held responsible for alignment, precision, and operang
funcons aer the mill has been disassembled. Test your mill before disassembling it.
The major sub-assemblies of spindle head, column, and base are bolted and dowelled together so
the mill can be separated into smaller components to meet very challenging transport problems.
Note, however, that this entails disconnecng wiring and the lubricaon lines. We recommend
taking photographs from all angles, including detailed photos of any wires or oil lines that will be
taken apart. Dowel pins must be removed before the bolts on disassembly. Dowel pins must be
installed before the bolts on re-assembly.
Contact Tormach Technical Support if more detailed advice is required.