Chapter 7
124
UM10350_PCNC770_Manual_0916A
Programming
When G92 is executed, it is applied to the origins of all coordinate systems (G54-G59.3). For example,
suppose the current controlled point is at X=4 and there is currently no G92 oset acve. Then G92
X7 is programmed. This reassigns the current controlled point to X=7, eecvely moving the origin
of the acve coordinate system -3 units in X. The origins of all inacve coordinate systems also move
-3 units in X. This -3 is saved in parameter 5211.
G92 osets may be already be in eect when the G92 is called. If this is the case, the oset is
replaced with a new oset that makes the current point become the specied value. It is an error if:
• All axis words are omied
The operang system stores the G92 osets and reuses them on the next run of a program. To
prevent this, one can program a G92.1 (to erase them), or program a G92.2 (to stop them being
applied – they are sll stored).
G92.1 – Reset axis osets to zero and sets parameters 5211 - 5219 to zero
G92.2 – Reset axis osets to zero
G92.3 – Sets the axis oset to the values saved in parameters 5211 to 5219
7.6.2.11 Feed Rate Mode – G93, G94 and G95
To set the acve feed rate mode to inverse me, program: G93
Inverse me is used to program simultaneous coordinated linear and coordinated rotary moon.
In inverse me feed rate mode, an F word means the move should be completed in [one divided by
the F number] minutes. For example, if the F number is 2.0, the move should be completed in half
a minute.
When the inverse me feed rate mode is acve, an F word must appear on every line which has a
G01, G02, or G03 moon, and an F word on a line that does not have G01, G02, or G03 is ignored.
Being in inverse me feed rate mode does not aect G00 (rapid traverse) moons.
To set the acve feed rate mode to units per minute mode, program: G94
In units per minute feed rate mode, an F word is interpreted to mean the controlled point should
move at a certain number of inches per minute, or millimeters per minute, depending upon what
length units are being used.
To set the acve feed rate mode to units per revoluon mode, program: G95
In units per revoluon mode, an F word is interpreted to mean the controlled point should move a
certain number of inches per revoluon of the spindle, depending on what length units are being
used. G95 is not suitable for threading, for threading use G33 or G76.