5. Remove the piece of foam from under the bucket mechanism.
1 Spirit level
2 Piece of foam
3 Fixing screws
6. To make sure that the rain gauge operates correctly, check that its rim is leveled
precisely.
Use a spirit level and adjust with the
fixing screws.
7. Connect the sensor cable.
More Information
‣
Connecting Sensor and Device Cables (page 218)
16.4
Installing OTT Pluvio
2
L
Install OTT Pluvio
2
L on a galvanized steel pedestal with an external diameter of
100 … 120 mm (3.94 … 4.72 in).
The default installation does not include a wind shield. If your delivery includes one, see
manufacturer documentation for details.
Chapter 16 – Precipitation Sensor Installation
207